img

Wechat

Adv. Search

J4 ›› 2010, Vol. 18 ›› Issue (5): 123-124.

• article • Previous Articles    

Determination of Main and Minor Components in Iron Ores by X-ray Spectormetry

LUO Xuehui,CHEN Zhansheng,CHEN Xue,LI Xuanhui   

  1. Gold Geological Institute of CAPF,Langfang 065000,Hebei,China
  • Received:2010-03-24 Revised:2010-09-15 Online:2010-10-28 Published:2012-05-23

Abstract:

The samples were made into a glass melting piece at 1 050 ℃ with [m(Li2B4O7)∶m(LiBO2)∶m(LiF)=4.5∶1∶0.4] as flux at a dilution of 1∶30.The elements includingFe、Si、Al、Mg、Ca、Na、K、P in the melting piece were simultaneously determined by X-ray spectrometry.The calibration curve was carried out with the standard samples. Whose determination results obtained by X-ray fluorescence were calibrated with a theoretical a-coefficient.Results obtained by the method were in good accordance with those values determined by chemical methods.Relative standard deviation(n=10)for each component were in the range of 0.43%~5.86%.

Key words: X-ray spectormetry, Iron ores, Fusion beads

CLC Number: 

  • O657.34

[1]李国会.X 射线荧光光谱法测定铬铁矿中主次量组分[J].岩矿测试,1999,18(2):131-134.
[2]武汉大学.分析化学实验[M].第3 版.北京:高等教育出版社,1994:155-160.
[3]童晓民,赵宏风,黄春燕,等.X 射线光谱法测定炉渣中13种组分[J].冶金分析,2005,25(6):12-15.
[4]吴静,王富仲,许增平.熔融制样X 射线荧光光谱法测定铁矿石中主次成分[J].冶金分析,2009,29(9):40-43.