基于FLUENT的深井掘进巷道局部通风参数优化
|
郭对明,李国清,侯杰,胡乃联
|
Optimization of Local Ventilation Parameters of Deep Mine Excavation Roadway Based on FLUENT
|
Duiming GUO,Guoqing LI,Jie HOU,Nailian HU
|
|
表3 各测点实测温度与模拟温度对比
|
Table 3 Comparison of measured temperature and simulated temperature at each measuring point(℃)
|
|
截面 位置/m | 测点a | 测点b | 测点c | 测点d | 测点e |
---|
实测值 | 模拟值 | 实测值 | 模拟值 | 实测值 | 模拟值 | 实测值 | 模拟值 | 实测值 | 模拟值 |
---|
0 | 26.200 | 26.336 | 26.100 | 26.266 | 26.400 | 26.496 | 26.500 | 26.636 | 26.700 | 26.886 | 10 | 25.900 | 26.216 | 25.800 | 26.076 | 26.000 | 26.376 | 26.100 | 26.316 | 26.300 | 26.266 | 20 | 26.100 | 26.252 | 26.100 | 26.392 | 26.200 | 26.412 | 26.200 | 26.402 | 26.200 | 26.372 | 30 | 26.300 | 26.276 | 26.100 | 26.416 | 26.300 | 26.436 | 26.200 | 26.526 | 26.500 | 26.586 | 40 | 26.100 | 26.312 | 26.200 | 26.452 | 26.400 | 26.422 | 26.400 | 26.662 | 26.600 | 26.712 | 50 | 26.200 | 26.328 | 26.500 | 26.468 | 26.200 | 26.438 | 26.400 | 26.778 | 26.700 | 26.718 | 60 | 26.300 | 26.340 | 26.300 | 26.480 | 26.400 | 26.450 | 26.700 | 26.840 | 27.000 | 26.810 |
|
|
|